Precautions for the use of intelligent electromagnetic flow meter

by:Kaidi Sensors     2022-08-29
Abstract: The information on the precautions in the early use of intelligent electromagnetic flowmeters is provided by excellent flowmeter and flowmeter manufacturers. Before the intelligent electromagnetic flowmeter is put into operation, we must check whether the flowmeter can operate normally. The use of the flowmeter should pay attention to the following issues: 1. Trial operation, whether it is a newly designed flowmeter or a newly installed flowmeter measurement system ;pass me. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the article on the precautions for the use of intelligent electromagnetic flowmeters. Before the intelligent electromagnetic flowmeter is put into operation, we need to check whether the flowmeter can operate normally. The use of the flowmeter should pay attention to the following issues: 1. Trial operation, whether it is a newly selected design or a newly installed flowmeter measurement system ; After our installation inspection and confirmation, the test run should be checked. During the trial operation, we must follow the following procedures: 1. First, close the on-off valve and regulating valve of the flowmeter; then, slowly open the bypass valve. 2. Finally, start the flowmeter to work. When starting the flowmeter, there will be some problems: 1. For the flowmeter with electrical remote transmission, first connect the power line and the signal line to warm up. Our solution is: first slowly open the on-off valve in front of the flowmeter; then slowly open the regulating valve behind the flowmeter; finally, slowly close the bypass valve to make the flowmeter work under normal flow. ②When the temperature of the measured fluid is very high, and the temperature difference with the ambient temperature is very large. Our solution is: at this time, the metering system should be preheated; the flowmeter and the pipeline system should be slowly heated up, so as to ensure the normal operation of the flowmeter. 3. After that, we observe and record the changing state of various operating parameters, such as temperature, pressure, etc. If the system does not have too much vibration, noise and leakage; and, after a period of stable operation, the trial operation ends. 2. Normal operation After normal operation, we can put it into normal operation. In the operation process, to use and maintain the flowmeter; the operator should do the following: 1. Regularly check and maintain the measurement system. Operators check flow meters, valves and piping systems. The maintenance of the equipment by the operator is mainly in: a. Protection equipment such as safety valve, restrictor valve and alarm; b. Flow auxiliary equipment such as flow display instrument, recording device, compensation device; c. Ancillary equipment such as filter and air eliminator . 2. For the work of starting and closing the flowmeter, we must follow the sequence of the test run. 3. During normal operation, the operator should always pay attention to the pressure, temperature, flow, viscosity and other parameters of the measured medium; see if these parameters meet the use range of the flowmeter. Reference: Intelligent electromagnetic flowmeter, . The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Precautions for the use of smart electromagnetic flow meters'
Most places have a few choices when it comes to customized level indicator level gauge distributors, but it can sometimes be difficult to find the right supplier for your needs. The quality of level gauge is critical to customized level indicator.
A detailed plan must be developed if we hope to reach your profitability goal. Once we have a certain figure in mind, Guangdong Kaidi Energy Technology Co., Ltd. and our staff need to determine all the steps necessary to reach that goal and act on them.
By investing in an ethical supply chain, Guangdong Kaidi Energy Technology Co., Ltd. position ourselves to engage with a driven, engaged customer base.
Our company specializes in manufacturing level gauge mainly customized level indicator.
[拓展名称] include a great variety of devices with a wide range of complexity: from simple customized level indicator used since prehistoric times to the complex of modern mechanized customized level indicator.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...