Precautions for Selection of Electromagnetic Flow Meters

by:Kaidi Sensors     2022-07-19
Abstract: The information on the selection of electromagnetic flowmeters is provided by the excellent flowmeter and flowmeter manufacturers. 1. Electromagnetic flowmeters have requirements for straight pipes before and after installation, but they are lower than other types of flowmeters, but the most critical point must be satisfied: that is, full pipes. When the tube is not full, it is easy to cause the flowmeter to jump randomly. Second, the measuring range of electromagnetic flowmeter. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the article on the selection of electromagnetic flowmeters. 1. Electromagnetic flowmeters have requirements for straight pipes before and after installation, but they are lower than other types of flowmeters, but the most critical point must be satisfied: that is, full pipes. When the tube is not full, it is easy to cause the flowmeter to jump randomly. 2. The measurement range of the electromagnetic flowmeter is limited. Many users often compare it with the water meter when ordering the meter, thinking that it can measure a very low flow rate. In fact, the order cannot be ordered according to the original pipe diameter. Flow to determine the diameter of the instrument. 3. The electromagnetic flowmeter also has a protection level. If the user has requirements for the installation environment of the instrument, and the installation site is in an underground well or some other humid places, it is recommended that the user choose a split type. In order to avoid damage to the instrument due to wrong selection. 4. The electromagnetic flowmeter can measure corrosive liquids, but at the beginning of the order, the user should correctly provide the name of the medium and its properties, so as to avoid mistakes in the selection of electrode materials during model selection, which will cause the sensor to be scrapped in the later use process. inconvenience and financial loss. 5. Although the electromagnetic flowmeter has good reliability and is usually not damaged, due to its principle, the electrode surface of the sensor has been in contact with the liquid. After a long time, the electrode surface is more likely to be polluted. Therefore, under the normal use of the electromagnetic flowmeter, if the user has the conditions to disassemble it, it is recommended that the electrode be disassembled and cleaned once a year to one and a half years to ensure the measurement accuracy of the entire flowmeter. Any instrumentation requires maintenance, and electromagnetic flowmeters are no exception. With the development of the industrial industry, the demand for instruments and meters has increased, the instrumentation industry has continued to develop, and the use of electromagnetic flowmeters has become more and more extensive, which can adapt to the needs of different industries, such as petroleum, chemical, sewage treatment and so on. The quality of the current domestic electromagnetic flowmeters is completely comparable to similar imported products from abroad, and the functionality, stability and accuracy are getting higher and higher. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Precautions for Selection of Electromagnetic Flow Meters'
Guangdong Kaidi Energy Technology Co., Ltd. is famous for creating innovative products like the level gauge and supporting their market leadership with savvy marketing campaigns to build an elite brand.
To learn more about level gauge, give us a call at Guangdong Kaidi Energy Technology Co., Ltd. or visit us online by going to Kaidi level indicator.
Knowing what promotions are popular and get the most activity as level gauge from current and potential customers can play a role in your overall strategy.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...