Magnetic flap
level gauge is also called magnetic column level gauge. The parameters that need to be known when purchasing are certain. For example, corrosive media require anti-corrosion materials, and the level of anti-corrosion varies according to the corrosive level of the medium. Determine the installation method of the magnetic flap liquid level gauge according to the situation of the equipment. 1. In the place where the equipment is running, the manufacturer can determine the material used for the equipment according to the measuring medium; 2. The main pipe should be cleaned irregularly according to the medium condition to remove impurities; 3. When the magnetic flap level gauge is equipped with a remote transmission instrument, it should Pay attention to the following aspects: a. The sensing surface of the remote transmission supporting instrument is close to and facing the main pipe; b. The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the liquid level gauge; c. Close to the main pipe of the liquid level gauge, and fix it with a stainless steel hoop (iron is prohibited); d. The connection between the remote transmission supporting instrument and the display instrument is best to be laid with a shielded two-core cable or a protective pipe alone; e. After the junction box inlet hole is laid, it is required to be well sealed to prevent rain, moisture, etc. from invading and causing the remote transmission supporting instrument to not work normally. The junction box should be covered in time after the maintenance or debugging is completed. 4. For magnetic flap level gauges with a length exceeding a certain length (ordinary type > 3 meters, anti-corrosion type > 2 meters): it is necessary to add intermediate reinforcement flanges or lugs as fixed supports to strengthen the strength and overcome its own weight 5. The installation position of the magnetic flap liquid level gauge: it should avoid or keep away from the inlet and outlet of the medium to avoid rapid local changes in the fluid, which will affect the accuracy of the liquid level measurement. 6. Precautions for debugging the magnetic flap liquid level gauge: the upper valve should be opened first, and then the lower valve should be opened slowly to let the medium enter the main pipe smoothly and slowly (the rapid impact of the medium on the float will cause the float to fluctuate dramatically and affect the display accuracy), Observe whether the turning of the magnetic red and white ball is normal, then close the valve of the lower lead pipe, open the drain valve, and let the liquid level in the main pipe drop.
If you are looking for an effective and safe way to take care of customized level indicator, then level gauge customized level indicator are the best bet.
As a result, consumers will reward KAIDI with leadership sales, profit, and value creation, allowing our customers in which we live and work to prosper.
level gauge developed from Guangdong Kaidi Energy Technology Co., Ltd.’s unique skills in high technology has helped to produce level gaugecustomized level indicator.
People tend to want what they perceive they cannot have. Making KAIDI seems exclusive or as if it will go out of stock if they don't act quickly often makes it more enticing to the consumer and increases the likelihood that they will buy in.