KS series temperature transmitter, using PT100 temperature sensor as the sensitive element, using computer laser resistance control temperature compensation, using integrated junction box design. With professional terminal and digital display, easy installation, calibration, maintenance.
This series of products are suitable for petroleum, water conservancy, chemical industry, metallurgy, electric power, scientific research, environmental protection and other enterprises and institutions, to achieve the measurement of fluid temperature and suitable for various occasions all-weather environment and various corrosive fluids.
◓ Multiple range options;
◓ Easy to adjust zero point and range; reverse polarity protection and current limit protection;
◓ Anti-lightning and impact resistance;
◓ Small size, beautiful appearance, high cost performance;
◓ High precision, high stability, and high reliability;
Measuring range | 0-1000℃ | Accuracy | 0.50% |
Overload capacity | 200% | Signal output | 4~20mA/RS485 |
Stability | ≤0.1%/year | Supply voltage | 18~36VDC |
Ambient temperature | -20℃~70℃ | Relative humidity | ≤80% |
Mounting thread | M20*1.5 | Interface material | stainless steel |
Signal terminals are arranged in the independent compartment of the electrical box. When wiring, you can unscrew the table cover on the wiring side. Power supply is connected to the transmitter through the signal line, no additional signal line can be used twisted-pair. In the case of serious electromagnetic interference, shielded wires and proper grounding are recommended. Do not put signal cables through metal pipes or in the same slot with other power cables. Do not pass signal cables near strong electric devices.
Threading holes in the electrical housing of the transmitter shall be sealed or plugged (with sealant) to prevent moisture accumulation in the electrical housing. If the threading hole is not sealed, the transmitter should be installed with the threading hole facing down in order to remove liquid.
The signal line may also float or be grounded at any point in the signal loop and the transmitter housing may be grounded or ungrounded.
Because the transmitter is grounded through capacitive coupling, the insulation resistance cannot be checked with a meg-ohmmeter higher than 100V, and the circuit should be checked with a voltage not greater than 45V.
KS-P202 | Industrial temperature transmitter | |
Threaded interface | N12 | 1/2NPTM |
M27 | Outside the M20 * 1.5 | |
N00 | Special order available | |
Display | W | No |
Signal output | I | 4~20mA |
R | RS485 | |
Range | (...) | Fill in as required |
Rod length | L...mm | Rod length |
Please Send Us your Application details
Measuring range , medium, Installation method (flange, thread), Pressure range, Remote transmitter, Level alarm switch
More Model available for all appication, different termperture and pressure!
We are here to help you! If you close the chatbox, you will automatically receive a response from us via email. Please be sure to leave your contact details so that we can better assist
Our technical team will check your specifications and make a best solution for you.