Intelligent electromagnetic flowmeter

by:Kaidi Sensors     2022-08-30
Abstract: Intelligent electromagnetic flowmeter information is provided to you by excellent flowmeter and flowmeter production and quotation manufacturers. Intelligent electromagnetic flowmeters are now more and more well-known and widely recognized, as long as the medium has a certain conductivity, the flow value measurement in the pipeline transportation process can be effectively measured by intelligent electromagnetic flowmeters, and the accuracy High, stable use. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the article on intelligent electromagnetic flowmeters. Intelligent electromagnetic flowmeters are now more and more well-known and widely recognized, as long as the medium has a certain conductivity, the flow value measurement in the pipeline transportation process can be effectively measured by intelligent electromagnetic flowmeters, and the accuracy High, stable and durable in use, easy to maintain. The intelligent electromagnetic flowmeter is mainly measured according to the Faraday principle. The diameter of the measuring pipe ranges from DN10 to DN2000 or even higher. It can be applied to different media and can easily cope with corrosive media by changing the inner material. Here are some common problems related to intelligent electromagnetic flowmeters ①How are intelligent electromagnetic flowmeters classified? According to the structure, it can be divided into integrated type and split type electromagnetic flowmeter, and according to the installation form, it can be divided into flange type and insertion type electromagnetic flowmeter (there is also a clamp type, which is not common. It is fixed by pipe clamping. Not extensive, usually customized for the project). ②What are the characteristics of intelligent electromagnetic flowmeter? A: As long as the medium is conductive, basically the measurement results will not be affected by temperature, pressure, density, viscosity and other parameters. B: Since the measurement principle of the electromagnetic flowmeter is the Faraday principle, there is no need to use equipment such as turbine blades for conversion measurement, and the lack of these components means that its measurement does not affect the pipeline. medium raw flow and pressure values. C: Pipe diameter has wide adaptability. The electromagnetic flowmeter can be as small as DN10mm, and the maximum can realize the flow velocity measurement of DN3000mm super-large pipeline. D: Different measurement environments may require replacement of electrodes. E: High measurement accuracy, which can stably maintain the accuracy at a high industrial accuracy level of 0.5%; F: Dual measurement functions with instantaneous flow and cumulative flow; G: Support remote signal transmission, 16-bit converter, easy to set up; H : Widely used in the industry, basically suitable for various occasions In the medium flow measurement in this industry, as long as the medium meets a certain conductivity, the integrated electromagnetic flowmeter can be used for installation and measurement. ③ Problems that need to be considered in advance when installing the intelligent electromagnetic flowmeter A: The vibration of the pipeline should not be too high, otherwise it will affect the stability; B: Keep away from the interference of the electromagnetic field, which will affect the accuracy of the measurement results; C: Avoid corrosion in the environment Inert gas directly affects the effective life of the entire electromagnetic flowmeter; D: The ambient temperature should not be too high, otherwise the internal components of the integrated electromagnetic flowmeter will be damaged; E: Proper moisture-proof and anti-exposure (long-term). ④ Where is the installation location of the intelligent electromagnetic flowmeter suitable? ⑤ Selection of intelligent electromagnetic flowmeter? Model caliber (pass through) Model code interpretation of intelligent electromagnetic flowmeters Form AC (alternating current) 220VAC50Hz (90~245VAC50Hz) DC (direct current) 24VDC (20~36VDC) LD lithium battery power supply (without signal output) code IfRsHC medium temperature≤65℃≤120℃≤180°C (only for split type) code lining material NE neoprene (≤65℃) PVC polyvinyl chloride (≤70℃) PU polyurethane wear resistance (≤80℃) PTFE polytetrafluoroethylene (≤180℃) code electrode material 316L stainless steel HC Hastelloy CTi titanium Ta tantalum Pt platinum Reminder: flowmeter selection must, medium, diameter (flow range), electrode material, lining material, installation method The above is the whole content of this article, You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Intelligent Electromagnetic Flowmeter'
Clouds of customized level indicator failures surround the world of customized level indicator in particular, simply because people don’t pay as much attention to the level gauge as they should do.
If you need level gauge solution, you should always consult a professional provider. Guangdong Kaidi Energy Technology Co., Ltd. is one such a competent provider that is highly qualified to offer a wide range of products and services. Visit today!
Guangdong Kaidi Energy Technology Co., Ltd. has extented its range of manufacturing scale, which satisfys customers' needs.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...