Abstract: Intelligent electromagnetic
flow meter installation specification information is provided by excellent flow meter and flow meter production and quotation manufacturers. Intelligent electromagnetic flowmeter installation specification (Wanjie Instrument Technology Knowledge) Jiangsu Wanjie Instrument Technology Co., Ltd. Intelligent electromagnetic flowmeter The unstable situation was originally caused by non-standard installation. Today, we will follow our company's technical staff to understand. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the article on the installation specification of intelligent electromagnetic flowmeters. Intelligent electromagnetic flowmeter installation specification The unstable situation of the intelligent electromagnetic flowmeter was originally caused by the non-standard installation. Today, we will follow the technical staff of our company to understand how to install the intelligent electromagnetic flowmeter correctly. First, the installation specifications of the sensor 1. The requirements of the installation site Generally, the protection of the electromagnetic flow sensor shell is extremely IP67, and the following requirements are required for the installation site. 1) When measuring mixed-phase fluids, choose a place that will not cause phase separation; when measuring two-component liquids, avoid installing them downstream where the mixing is not uniform; when measuring chemical reaction pipelines, install them downstream of the fully completed reaction section; 2 ) Avoid negative pressure in the measuring tube as much as possible; 3) Choose a place with little vibration, especially for integrated instruments; 4) Avoid large motors, large transformers, etc. nearby, so as to avoid electromagnetic field interference; 5) It is easy to realize the independent grounding of the sensor 6) Avoid high concentrations of corrosive gases in the surrounding environment as much as possible; 7) The ambient temperature is in the range of -25/-10~50/600℃, and the temperature of the integrated structure is also limited by the electronic components, so the range should be narrower 8) Avoid direct sunlight as much as possible; 2. Requirements for installing straight pipe sections First of all, pay attention to the fact that the sensor itself cannot be used as a load support point, it cannot support the adjacent working pipeline, and the pipeline that clamps it should be load-bearing. In order to obtain normal measurement accuracy, there should also be a certain length of straight pipe upstream of the electromagnetic flow sensor, but its length is lower than that of most other flow meters. 90ºElbow, T-shaped pipe, concentric reducer, and a straight pipe section with a length of 5 times the diameter (5D) from the flange connection surface at the inlet end of the sensor after the fully open gate valve, and 10D for valves with different opening degrees; the downstream straight pipe section is ( 2~3) D; but it is necessary to prevent the butterfly valve from protruding into the measuring tube of the sensor. The lengths of upstream and downstream straight pipe sections proposed by various standards or verification regulations are also inconsistent, and some electromagnetic flowmeters have higher requirements than usual. This is because to ensure that the requirements of the current 0.5-level precision instrument are met. 3. Installation position and flow direction The installation direction of the sensor can be horizontal, vertical or inclined (the fluid must flow horizontally or inclined upward) without restriction. But make sure that the measuring tube is coaxial with the process pipeline. The deviation of its axis shall not exceed 2MM. When measuring solid-liquid two-phase fluids, it is best to install vertically and flow from bottom to top. This can avoid serious local wear of the lower half of the lining during horizontal installation, and solid phase precipitation at low flow rates. When the sensor is adjacent to the pipeline for welding or flame cutting, isolation measures should be taken to prevent the lining from being heated, and it must be confirmed that the signal line of the instrument converter is not connected to prevent damage. When the converter is installed horizontally, the axis of the electrode should be parallel to the horizon, not perpendicular to the For the horizon, because the electrode at the ground is easily covered by sediment, the top electrode is easily wiped by the occasional air bubbles in the liquid to cover the surface of the electrode, causing the output signal to fluctuate. 4. The installation of negative pressure piping systems Fluoroplastic lined sensors must be carefully applied to negative pressure piping systems; positive pressure piping systems should prevent negative pressure, such as piping systems with liquid temperature higher than room temperature, close the upstream and downstream stop valves of the sensor to stop running After the fluid cooling and shrinking, a negative pressure will be formed. A negative pressure prevention valve should be installed near the sensor. The manufacturer stipulates that the pressure of PTFE and PFA plastic lining applied to the negative pressure piping system can be used at 200C, 1000C, and 1300C. The absolute pressure must be For non-conductive pipes, respectively, the grounding flange is clamped between the sensor flange and the pipe flange. 5. The grounding sensor must be grounded separately (grounding resistance 10Ωthe following). In principle, the grounding of the separate type should be on the sensor side, and the grounding of the converter should be at the same grounding point. If the sensor is installed on a pipeline with cathodic corrosion protection, in addition to grounding the sensor and the grounding ring together, a thicker copper wire (16mm) should be used to bypass the two connecting flanges of the sensor across the pipeline, so that the cathodic protection current flows between the sensors. isolation. Sometimes the stray current is too large. If the leakage current of the electrolytic cell along the electrolyte affects the normal measurement of EMF, the method of electrical isolation between the flow sensor and the process to which it is connected can be taken. This method can also be adopted when the cathodic protection current affects the EMF measurement on pipelines with cathodic protection as well.
When you find yourself in need of level gauge customized level indicator, you may not know where to begin. And that's OK! Search out Guangdong Kaidi Energy Technology Co., Ltd. to handle your level gauge needs.
Helping the needy customized level indicator industries with quality products had been our main goal and we have succeeded in providing simple and effective solutions which has a huge scope to be implemented in the near future. Go to Kaidi level indicator to know more about us.
Like anything else in customized level indicator, there are a variety of choices and types to choose from, and each of them will affect your budget in some form. Guangdong Kaidi Energy Technology Co., Ltd. offers a range of quality at competitive prices.