Abstract: The information on how to use and correctly install electromagnetic flowmeters is provided by excellent flowmeter and flowmeter manufacturers. How to use and install the electromagnetic flowmeter correctly: 1. The electromagnetic flowmeter should choose a straight pipe section filled with liquid, such as the vertical section of the pipeline (the flow direction is preferably from bottom to top) or the horizontal pipe full of liquid (the lowest point in the entire pipeline is should), during installation and measurement, no. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details on how to use and correctly install the electromagnetic flowmeter. How to use and install the electromagnetic flowmeter correctly: 1. The electromagnetic flowmeter should choose a straight pipe section filled with liquid, such as the vertical section of the pipeline (the flow direction is preferably from bottom to top) or the horizontal pipe full of liquid (the lowest point in the entire pipeline is 2. The measurement position should be selected at a place where the upstream is greater than 5D and the downstream has a 3D straight pipe section; 3. The measurement point should be selected as far as possible from pumps, valves and other equipment. Avoid its interference to the measurement; 4. The selection of the measurement point should be as far away as possible from high-power radio stations, strong magnetic field interference sources, etc. Special attention should be paid to the installation: the axis of the measuring electrode must be approximately horizontal; the measuring pipe must be completely filled with liquid;·The front of the flowmeter must be at least 5XAA as the inner diameter of the flowmeter), and there must be at least 3xD (D is the inner diameter of the flowmeter) in the back of the straight pipe. Festival.·The flow direction of the fluid is the same as the arrow direction of the flowmeter;·If there is a vacuum in the pipeline, the lining of the flowmeter will be damaged, and special attention should be paid;·There should be no strong electromagnetic field near the flowmeter;·There should be ample space near the flowmeter for installation and maintenance;·If the measurement pipeline vibrates, there should be fixed supports on both sides of the flowmeter;·When measuring mixed liquids of different media, the distance between the mixing point and the flow meter must be at least 30×D (D is the inner diameter of the flowmeter) length;·In order to facilitate the cleaning and maintenance of the flowmeter in the future, a bypass pipe should be installed, and a straight pipe section of 3D in front of the flowmeter and 3D in the back should be ensured. Ways to install a flowmeter in the measuring well·For example, when installing a PTFE lined flowmeter, the bolts connecting the two flanges should be tightened evenly, otherwise the PTFE lining will be easily crushed, and a torque wrench is best. Installation requirements should be installed at the lower part of the horizontal pipeline and vertically upward, and avoid installing it at the highest point of the pipeline and vertically downward;·Should be installed on the rise of the pipeline;·Installed in an open discharge pipeline, it should be installed at the lower part of the pipeline;·If the pipeline drop exceeds 5m, install an exhaust valve downstream of the sensor;·Control valves and shut-off valves should be installed downstream of the sensor, not upstream of the sensor;·The sensor must not be installed at the inlet and outlet of the pump, but should be installed at the outlet of the pump; the above is the whole content of this article, you are welcome to inquire about the flowmeter selection and quotation of our factory. 'How to Use and Correctly Install Electromagnetic Flow Meters'
Guangdong Kaidi Energy Technology Co., Ltd. has a great reputation on producing innovative products as the level gauge.
And finally, if you want to find additional resources for level gauge, simply go to Kaidi level indicator for more.
First, in sparking the initial idea for a company based on manufacturing technology; and second, in designing a solution that could meet a clear market need for solving issues related to level gauge customized level indicator.
The unique connections between level gaugemanufacturing and customers happen when you find ways to relate on a more personal and engaging level that goes beyond a product.
Guangdong Kaidi Energy Technology Co., Ltd. has a great reputation on producing innovative products as the level gauge.
And finally, if you want to find additional resources for level gauge, simply go to Kaidi level indicator for more.
First, in sparking the initial idea for a company based on manufacturing technology; and second, in designing a solution that could meet a clear market need for solving issues related to level gauge customized level indicator.
The unique connections between level gaugemanufacturing and customers happen when you find ways to relate on a more personal and engaging level that goes beyond a product.
Custom message