Abstract: Electromagnetic
flowmeter installation specification information is provided by excellent flowmeter and flowmeter production and quotation manufacturers. The introduction of
electromagnetic flowmeter installation specifications, including the requirements of electromagnetic flowmeter installation environment, the selection of electromagnetic flowmeter installation location, the installation method of electromagnetic flowmeter and other specifications, more installation specifications electromagnetic flowmeter manufacturers will answer for you. . More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the electromagnetic flowmeter installation specification article. Last time, we introduced the detailed explanation of the electromagnetic flowmeter installation with pictures and texts. Today, we will introduce the electromagnetic flowmeter installation specifications in depth again, the in-depth introduction of the electromagnetic flowmeter installation environment specifications, the electromagnetic flowmeter installation pipeline location selection specifications, and the electromagnetic flowmeter installation method. Specifications, etc., to prevent you from stepping on thunder during the installation of electromagnetic flowmeters. In unconventional circumstances, you can also ask our flowmeter engineers for specifications in special environments. 1: Selection of installation environment for electromagnetic flowmeter installation specifications ①: Ensure that the pipeline is fixed and cannot vibrate, and the vibrating pipeline is not conducive to the long-term operation of the electromagnetic flowmeter; ②: It is necessary to keep the installation environment of the electromagnetic flowmeter away from the interference of the magnetic field; ③: There should be enough maintenance space in the electromagnetic flowmeter installation environment, too narrow space is not conducive to the maintenance and management of the electromagnetic flowmeter in the later stage; ④: Avoid the coexistence of corrosive gases in the environment, and the coexistence of corrosive gases for a long time will affect The service life of the electromagnetic flowmeter; ⑤: The installation environment temperature should not be too high, so as not to damage the internal parts of the flowmeter; ⑥: The electromagnetic flowmeter should be installed indoors or in a sheltered place as much as possible. If it must be installed outdoors, try to use rain It is not necessary to install the shed for moisture-proof and sun protection, but it can ensure the longer-lasting operation of the flowmeter itself. 2: Selection of the location of the electromagnetic flowmeter installation specification“full tube”Otherwise, if the tube is not satisfied, the conductivity of the medium is required for the measurement of the electromagnetic flowmeter, and the instability of the conductivity will directly affect the measurement accuracy of the electromagnetic flowmeter when the tube is not satisfied or the air is intervened. Secondly, if the electromagnetic flowmeter is applied in the measuring well, its installation position is suggested as shown in the figure: The figure of the installation position of the electromagnetic flowmeter in the measuring well is interpreted as follows: 1: inlet, 2: overflow pipe, 3: inlet grille, 4: cleaning Hole, 5: Flowmeter, 6: Short pipe, 7: Outlet, 8: Drain valve Specification of installation method ①: Ensure that the axis of the electromagnetic flowmeter is in a horizontal position; ②: The pipeline must be full, and the reasons are explained above; ③: The flow direction of the medium and the pipeline must be consistent with the direction of the arrow indicated on the electromagnetic flowmeter; ④: Installation Location, the position of the pipeline where the electromagnetic flowmeter is installed should at least meet the straight pipe sections of the first 5 and the last 3 (5 and 3 correspond to multiples of the inner diameter of the pipeline respectively). Manufacturer's flowmeter selection, quotation, etc. 'Electromagnetic Flowmeter Installation Specification'
It is beyond doubt that benefits customized level indicator. Market sentiments are strong, especially in the light of growing customized level indicator observed globally.
Guangdong Kaidi Energy Technology Co., Ltd. has had manufacturing experience for over customized level indicator years. She currently runs a website where they sell . You can visit her site at Kaidi level indicator.
But loyalty programs aren't just a boon for customers – KAIDI gets access to tons of valuable data for opt-in marketing campaigns.
customized level indicator level gauge quality is more important because some how it affects to our customized level indicator. So grab good quality .