Abstract: Electromagnetic
flow meter installation tips information is provided by excellent flow meter and flow meter production and quotation manufacturers. Chengfeng Instrument's intelligent electromagnetic flowmeter is developed based on a standardized manufacturing system. Its advanced design concept ensures the high precision and high reliability of the product. Compared with the old electromagnetic flowmeter, it has high measurement accuracy and reliability. Strong and stable. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the article on the installation tips of electromagnetic flowmeters. The intelligent electromagnetic flowmeter is developed based on the standardized manufacturing system. Its advanced design concept ensures the high precision and high reliability of the product. Compared with the old electromagnetic flowmeter, it has high measurement accuracy, strong reliability and stability. With the advantages of good performance, complete functions and long service life, we can install the three blocks, as follows: 2. Requirements for installing straight pipe sections First of all, pay attention to the fact that the sensor itself cannot be used as a load support point, and it cannot support the adjacent working pipeline. The pipe holding it is load-bearing. In order to obtain normal measurement accuracy, there should also be a certain length of straight pipe upstream of the electromagnetic flow sensor, but its length is lower than that of most other flow meters. 90ºElbow, T-shaped pipe, concentric reducer, and a straight pipe section with a length of 5 times the diameter (5D) from the flange connection surface at the inlet end of the sensor after the fully open gate valve, and 10D for valves with different opening degrees; the downstream straight pipe section is ( 2~3) D; but it is necessary to prevent the butterfly valve from protruding into the measuring tube of the sensor. The lengths of upstream and downstream straight pipe sections proposed by various standards or verification regulations are also inconsistent, as shown in Table 2, and the requirements are higher than usual. This is because to ensure that the requirements of the current 0.5-level precision instrument are met. 1. Installation of the sensor 1) Avoid the negative pressure in the measuring tube as much as possible; 2) When measuring mixed-phase fluid, choose a place that will not cause phase separation; when measuring two-component liquid, avoid installing it downstream where the mixing is not uniform; When measuring the chemical reaction pipeline, it should be installed downstream of the fully completed reaction section; 3) Avoid high concentrations of corrosive gases in the surrounding environment as much as possible; 4) Avoid large motors, large transformers, etc. nearby, so as to avoid electromagnetic field interference; 5) Avoid direct sunlight as much as possible; 3. The axis of the installation position and flow direction of the measuring electrode must be similar to the horizontal direction; the measuring pipe must be completely filled with liquid; the front of the flowmeter must be at least 5xD (D is the inner diameter of the flowmeter) length. For the straight pipe section, there should be at least 3xD (D is the inner diameter of the flowmeter) straight pipe section behind; for easy installation and disassembly, a pipe expansion joint can be installed behind the flowmeter. The flow direction of the fluid is the same as the arrow direction of the flowmeter; if there is a vacuum in the pipeline, it will damage the lining of the flowmeter, so special attention should be paid; there should be no strong electromagnetic field near the flowmeter; there should be ample space near the flowmeter for installation and maintenance; if there is vibration in the measurement pipeline, there should be fixed supports on both sides of the flowmeter; when measuring mixed liquids of different media, the distance between the mixing point and the flowmeter should be at least 30×D (D is the inner diameter of the flowmeter) length. Electromagnetic flowmeter, a domestic high-end flowmeter brand, takes customer demand as the first priority, and puts quality first, so that customers can use it with confidence. The reputation of electromagnetic flowmeters in the industry and customer feedback are satisfactory: high precision, durability, long service life, low failure rate, and good after-sales service. These are the evaluations and affirmations of our customers, which are the driving force for our progress. We strive to develop new technologies, improve product performance, use high-quality materials, and be meticulous about product quality to ensure a 100% pass rate for production testing. , Only do high-quality products, customer satisfaction is our driving force. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Electromagnetic Flow Meter Installation Tips'
The use of customized level indicator level gauge is a great trend in today's world. What you should know is that it has become a very important part of business today.
Boasting good reputation in the industry, Guangdong Kaidi Energy Technology Co., Ltd. is the leading level gauge supplier, offering high quality and level gauge services for homes and enterprised all over the world. More info on Kaidi level indicator.
The first machine to produce customized level indicator, the customized level indicator level gauge was invented in customized level indicator in customized level indicator by customized level indicator and was subsequently improved.
level gauge has its grasp on oversees market and has a very good repute. Our products are available at very competitive prices.