DN80 electromagnetic flowmeter price
by:Kaidi Sensors
2022-09-17
Abstract: The price information of DN80 electromagnetic flowmeter is provided to you by excellent flowmeter and flowmeter manufacturers. I am honored to recommend the DN80 electromagnetic flowmeter, the core product of Huaian Runtai Instrument Co., Ltd., if you have any needs or suggestions, please contact us at 18252328670. The DN65 electromagnetic flowmeter can not only measure the volume flow of general conductive liquids, but also the volume flow of strong corrosive liquids such as strong acid and alkali, as well as the volume flow of uniform liquid-solid two-phase suspensions such as mud, pulp, and pulp. Widely used in petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, and river courses. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the DN80 electromagnetic flowmeter price article. I am honored to recommend the core product DN80 electromagnetic flowmeter of Huaian Runtai Instrument Co., Ltd. to you. If you have any needs or suggestions, please contact us at 18252328670. The DN65 electromagnetic flowmeter can not only measure the volume flow of general conductive liquids, but also the volume flow of strong corrosive liquids such as strong acid and alkali, as well as the volume flow of uniform liquid-solid two-phase suspensions such as mud, pulp, and pulp. Widely used in petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food and other industrial sectors and flow measurement in municipal management, water conservancy construction, river dredging and other fields. Working principle The measuring principle is based on Faraday's law of electromagnetic induction. That is to say, when the conductive liquid moves into the magnetic field to cut the magnetic field lines, an induced electromotive force is generated in the conductor, and its induced electromotive force E is: E = KBVDK = external constant B = magnetic induction intensity V = uniform flow rate D = measuring tube inner diameter, when measuring During flow, the fluid flows through a magnetic field perpendicular to the direction of movement. The activity of the conductive liquid induces a voltage proportional to the uniform flow rate (ie, volumetric flow rate), so the moving liquid needs to be measured. Its induction is detected by two electrodes in direct contact with the liquid and transmitted through a cable to an amplifier, which is then converted into a consistent output signal. This measurement method has the following advantages: 1. Measure the unobstructed part of the pipeline so that no additional pressure is lost. 2. Because the signal is formed in the entire space filled with the magnetic field, it is a uniform value across the pipe cross-section. Therefore, the straight pipe section from the electrode plane to the upstream end plane of the sensor is relatively short, with a length of 5×DN (DN is the inner diameter of the conduit). 3. Just touch the pipe and electrode with the liquid to be tested. Therefore, only reasonable selection of electrode and pipe lining data can meet the requirements of corrosion resistance and wear resistance. 4. The output signal of the sensor is an electromotive force that is linearly related to the uniform flow rate. 5. The measurement results have nothing to do with the physical parameters such as pressure, temperature, density, viscosity and electrical conductivity (not lower than the minimum electrical conductivity) of the liquid. The measurement accuracy is high and the task is arduous. The DN65 electromagnetic flowmeter is fully digitally processed, with strong anti-interference ability, reliable measurement, high precision, and the flow measurement range can reach 150:1. Using 16-bit embedded microprocessor, the operation speed is fast, the precision is high, and the programmable frequency is excited by the low-frequency rectangular wave, which improves the stability of flow measurement and has low power consumption. Using SMD devices and SMD technology, the circuit reliability is high. With no moving and free-flowing parts in the pipeline, there is little additional pressure loss in the measurement. In the field, the measurement range can be modified online according to the actual needs of users. The measurement results are independent of physical parameters such as velocity distribution, fluid pressure, temperature, density and viscosity. High-definition backlit LCD screen, full Chinese menu operation, easy to use, simple to operate, easy to learn and understand. With RS485, RS232, Hart and Modbus digital communication signal output. (Optional) With self-test and self-judgment functions. Hourly total recording function to record the total flow in hours. Suitable for time-of-use metering system (optional). There are three accumulators inside, which display forward accumulator, reverse accumulator and difference accumulator respectively. There is no power failure inside, and the time of 16 power failures can be recorded. (Optional) Infrared handheld operator, 115KHZ communication rate, all functions of remote non-contact operation converter (optional) DN65 electromagnetic flowmeter technical parameters Nominal size (mm) (special specifications can be customized) Teflon tube type Lining: DN10~DN1200 Tubular Rubber Lining: DN40~DN1200 Flow Direction: Forward and Reverse, Net Flow Range Ratio: 150: 1 Repeatability Error: 0.1% of the measured value Accuracy class: Pipe type: 0.5 class, Class 1.0 Measuring medium temperature: ordinary rubber lining: -20℃~+60℃ high temperature rubber lining: -20℃~+90℃ PTFE lining: -30℃~+100℃ high temperature tetrafluoroethylene lining: -20℃~ +180℃ Rated working pressure: (high pressure can be customized) DN6-DN80: ≤ 1.6 0.15m/s Conductivity range: measured fluid conductivity ≥ 5μs/cm Current output: Load resistance 0 ~ 10ma: 0 ~ 1.5kω 4 ~ 20ma: 0 ~ 750kω When the external power supply ≤35V is turned on,The maximum collector current is 250 mA. Power supply: AC220V, DC24V or 3.6V battery requires the length of the straight pipe section upstream ≥ 5DN, downstream ≥ 2DN. Flange connection should be used between the flowmeter and the pipeline. The size of the flange connection should conform to the explosion-proof level specified in GB11988: mdIIBT4 protection level: IP65, and the highest special IP68 can be made. The above is the entire content of this article. selection, quotation, etc. 'DN80 electromagnetic flowmeter price'
Maintaining customized level indicator is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.
At the heart of level gauge is our Vision to be the global energy company most admired for its people, partnership and performance.
The risk of customized level indicator is reduced by customized level indicator with the consumption of .
Digging into our roots and acknowledging out heritage can be fruitful on both a high-quality and professional level of level gauge.
Guangdong Kaidi Energy Technology Co., Ltd. must adopts new technology and internal procedures to increase responsiveness and mitigate costs going forward.
Maintaining customized level indicator is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.
At the heart of level gauge is our Vision to be the global energy company most admired for its people, partnership and performance.
The risk of customized level indicator is reduced by customized level indicator with the consumption of .
Digging into our roots and acknowledging out heritage can be fruitful on both a high-quality and professional level of level gauge.
Guangdong Kaidi Energy Technology Co., Ltd. must adopts new technology and internal procedures to increase responsiveness and mitigate costs going forward.
Custom message