Diagram of installation requirements of electromagnetic flowmeter
by:Kaidi Sensors
2022-08-21
Abstract: The schematic information of electromagnetic flowmeter installation requirements is provided by the excellent flowmeter and flowmeter production and quotation manufacturers. Detailed diagrams of electromagnetic flowmeter installation requirements, graphic and text analysis of some requirements for electromagnetic flowmeter installation, electromagnetic flowmeter installation determines the later use, maintenance and measurement accuracy. This article mainly organizes the installation location, installation method and other precautions. . For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the detailed article of the installation requirements of electromagnetic flowmeters. Detailed diagrams of electromagnetic flowmeter installation requirements, graphic and text analysis of some requirements for electromagnetic flowmeter installation, electromagnetic flowmeter installation determines the later use, maintenance and measurement accuracy. This article mainly organizes the installation location, installation method and other precautions. 1: Requirements for the installation environment of the electromagnetic flowmeter ①: It should be avoided to install in places with large temperature changes or high temperature radiation of the equipment. If it must be installed, thermal insulation and ventilation measures should be taken. ②: The electromagnetic flowmeter is installed indoors. If it must be installed outdoors, it should avoid rain, water immersion and sunlight, and should have moisture-proof and sun-proof measures. ③: The electromagnetic flowmeter should be avoided to be installed in the environment containing corrosive gas, and ventilation measures should be taken if necessary. ④: In order to facilitate installation, maintenance and maintenance, there should be enough installation space around the flowmeter. ⑤: Magnetic fields and strong vibration sources should be avoided where the flowmeter is installed. If the pipeline vibrates greatly, there should be brackets to fix the pipeline on both sides of the flowmeter. 2. The selection of the specific location of the electromagnetic flowmeter requires the installation location of the electromagnetic flowmeter in 6 different types of pipelines. Secondly, if the electromagnetic flowmeter is used in the measurement well, its installation location is recommended as shown in the figure: the electromagnetic flowmeter in the measurement well The numbers in the installation location diagram are interpreted as follows: 1: Inlet, 2: Overflow pipe, 3: Inlet grill, 4: Cleaning hole, 5: Flow meter, 6: Short pipe, 7: Outlet, 8: Drain valve Generally, solenoid Schematic diagram of the installation position of the flowmeter: The recommended installation position of the electromagnetic flowmeter and the position that should not be installed Diagram analysis 3: The method of installing the electromagnetic flowmeter in the pipeline (ie: how to install it on the pipeline?) ①: The axis (non-measurement electric level) should be in the Horizontal position ②: The pipeline to be measured should be filled with medium; ③: Before and after the installation point of the flowmeter should meet at least the first 5 and the last 3 straight pipe sections (the length of the inner diameter of the first 5 flowmeters and the length of the inner diameter of the 3 flowmeters); ④: The flow direction (direction) of the medium must be consistent with the arrow of the electromagnetic flowmeter; ⑤: There is no strong electromagnetic field nearby; ⑥: There is enough space for later maintenance (the conventional straight pipe section is sufficient, but the diameter is small. Care should be taken to leave enough room for maintenance). With this diagram of electromagnetic flowmeter installation requirements, I believe everyone has a clearer understanding of the installation of electromagnetic flowmeters. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Electromagnetic flowmeter installation requirements diagram'
Guangdong Kaidi Energy Technology Co., Ltd. outfits our businesses with level gauge because they're relatively affordable and highly customizable.
Boasting good reputation in the industry, Guangdong Kaidi Energy Technology Co., Ltd. is the leading level gauge supplier, offering high quality and level gauge services for homes and enterprised all over the world. More info on Kaidi level indicator.
Further dialogue of KAIDI between the approaches, the chapter concludes, could lead to actionable advice on more robust policies that drive both structural change and competitiveness upgrading.
According to the latest social survey, more than 50 percent of consumers (across all age demographics) follow a brand before purchasing a product. Therefore, KAIDI's content can make or break a customer's decision to conduct business with you.
The above are only part of the examples regarding level gauge, for more information, please click here Kaidi level indicator.
Guangdong Kaidi Energy Technology Co., Ltd. outfits our businesses with level gauge because they're relatively affordable and highly customizable.
Boasting good reputation in the industry, Guangdong Kaidi Energy Technology Co., Ltd. is the leading level gauge supplier, offering high quality and level gauge services for homes and enterprised all over the world. More info on Kaidi level indicator.
Further dialogue of KAIDI between the approaches, the chapter concludes, could lead to actionable advice on more robust policies that drive both structural change and competitiveness upgrading.
According to the latest social survey, more than 50 percent of consumers (across all age demographics) follow a brand before purchasing a product. Therefore, KAIDI's content can make or break a customer's decision to conduct business with you.
The above are only part of the examples regarding level gauge, for more information, please click here Kaidi level indicator.
Custom message