Detailed instructions to pay attention to when installing a split electromagnetic flow meter
by:Kaidi Sensors
2022-09-05
Abstract: The details and information that should be paid attention to when installing a split electromagnetic flow meter are provided by the excellent flow meter and flow meter production and quotation manufacturers. The split electromagnetic flowmeter is an instrument that can detect instantaneous flow and cumulative flow. As an important instrument in the environmental protection treatment industry, it plays a great role in the detection of water quality parameters in the environmental protection industry. At the same time, the split electromagnetic flowmeter has become various enterprises. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the installation of the split electromagnetic flowmeter meter to explain the details of the article. The split electromagnetic flowmeter is an instrument that can detect instantaneous flow and cumulative flow. As an important instrument in the environmental protection treatment industry, it plays a great role in the detection of water quality parameters in the environmental protection industry. At the same time, the split electromagnetic flowmeter has become the focus of attention of various enterprises, and enterprises are paying more and more attention to flowmeters! The principle of the split electromagnetic flowmeter is mainly based on Faraday's law of electromagnetic induction. In the flowmeter, the conductive medium in the measuring tube is equivalent to the conductive metal rod in the Faraday test, and the two electromagnetic coils at the upper and lower ends generate a constant magnetic field. When a conductive medium flows, an induced voltage is generated, and two electrodes inside the pipe measure the induced voltage. The measuring pipe is electromagnetically isolated from the fluid and the measuring electrodes by means of a non-conductive lining. The flowmeter is mainly composed of body, electrode, lining and converter. The material of the body is mainly carbon steel, followed by stainless steel. The lining material is mainly composed of rubber lining and tetrafluoro lining. The rubber lining is mainly suitable for wear-resistant media. As long as the rubber lining is neoprene and polyurethane rubber, polyurethane rubber is suitable for strong wear media. The tetrafluoro lining is mainly suitable for Corrosion-resistant medium, the tetrafluoroethylene substrate is mainly polytetrafluoroethylene and polyperfluoroethylene propylene, and the material of polytetrafluoroethylene propylene is suitable for strong abrasive media. Electrode materials are mainly divided into molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium tantalum, and stainless steel carbide Wu. Different materials have different prices, and different materials are used in different occasions. When purchasing a split electromagnetic flowmeter, it is necessary to detect indoors, measure outdoors, or need real-time monitoring. It is very important to choose a split electromagnetic flowmeter. big influence. Split-type electromagnetic flowmeter is an assembly method of electromagnetic flowmeter, that is, the sensor and the converter are installed in different places separately, and are often used in harsh industrial site environments or in environments with special requirements. Installation protection measures for split electromagnetic flowmeter: 1. The sensor should be installed vertically and flow up and down to meet the state of mixing solid and liquid. 2. It should be avoided as far as possible to install it on the pipeline with strong vibration. If it must be installed, the pipeline fastening device must be installed at the 2D upstream and downstream, and the anti-vibration pad should be added to strengthen the anti-vibration effect. 3. Try to avoid strong electrical equipment and strong electromagnetic fields during installation to avoid interference caused by magnetic fields , to facilitate the installation and wiring and regular maintenance of the split electromagnetic flowmeter. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Details to be paid attention to when installing a split electromagnetic flow meter'
As a entrepreneur, being trapped in a company under multiple quality problems never appealed to Guangdong Kaidi Energy Technology Co., Ltd..
Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Guangdong Kaidi Energy Technology Co., Ltd. will be able to fund our own growth by generating profits.
There have been conclusive evidence on 's role in customized level indicator and customized level indicator.
As a entrepreneur, being trapped in a company under multiple quality problems never appealed to Guangdong Kaidi Energy Technology Co., Ltd..
Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Guangdong Kaidi Energy Technology Co., Ltd. will be able to fund our own growth by generating profits.
There have been conclusive evidence on 's role in customized level indicator and customized level indicator.
Custom message