Abstract: The information on the correct installation method of electromagnetic
flowmeters is provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. 1. Horizontal and vertical installation The sensor can be installed horizontally and vertically, but it should be ensured to avoid the influence of deposits and air bubbles on the measuring electrode, and the electrode axis should be kept horizontal. When installed vertically, the fluid should flow from bottom to top. 2. Ensure that the full pipe is installed: . More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details of the correct installation method of electromagnetic flowmeters. 1. Horizontal and vertical installation The sensor can be installed horizontally and vertically, but it should be ensured to avoid the influence of deposits and air bubbles on the measuring electrode, and the electrode axis should be kept horizontal. When installed vertically, the fluid should flow from bottom to top. 2. Ensure full pipe installation: ensure that when the flow sensor is measuring, the pipe is full of the fluid to be measured, and the non-full pipe state cannot occur. If the pipeline is not full or the outlet is empty, the sensor should be installed on a siphon. 3. The sensor cannot be installed in the high position of the pipeline, which is easy to accumulate air bubbles 4. Installation between elbows, valves and pumps: In order to ensure the stability of the measurement, straight pipe sections should be set before and after the sensor, the length of which is shown in the figure below given. If this is not possible, a current stabilizer should be used or the cross-section of the measuring point should be reduced. 5. The inlet straight pipe section and the outlet straight pipe section of the sensor: the ideal installation site should select enough straight pipe sections before and after the measurement point. The inlet straight pipe section should be≥5D, outlet straight pipe section≥3D (D is the nominal diameter of the sensor). The plug-in inlet straight pipe section shall be≥ 20 D, outlet straight pipe section≥7D (D is the nominal diameter of the sensor) 6. Installation when the outlet of the pipeline is empty: When the outlet is in the empty state, the sensor should not be installed in the empty place of the pipeline, but should be installed at a lower place. When the sensor is installed under the pipeline, it should be ensured that the sensor is filled with liquid, and the empty pipe state cannot occur. 7. The sensor cannot be installed at the water inlet of the pump: in order to avoid negative pressure, the sensor cannot be installed at the water inlet of the pump, but should be installed at the water outlet of the pump. 8. Joint installation and parallel installation: If several sensors need to be connected in series on the same pipeline in sequence, the distance between each sensor should be at least the length of 2 sensors. If more than two sensors are installed in parallel with each other, the distance between the sensors must be greater than 1. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'The correct installation method of electromagnetic
flow meter'
At a time when technology is essential for level gauge, ensuring that it works in a symbiotic way with your human employees is key.
If you follow these straightforward steps you can keep your customized level indicator customized level indicator. I think this article will help you make a wise decision on choosing the right .
level gauge is receiving a great positive feedback in the market. And many of our clients are fully satisfied with it.