Classification and performance advantages of current transmitters

by:Kaidi Sensors     2021-12-28
The classification and performance advantages of current transmitters are introduced as follows: The classification of current transmitters    current transmitters are divided into two types: DC current transmitters and AC current transmitters. The AC current transmitter is an instrument that can convert the measured AC current into a DC voltage or DC current in a linear proportion. The product is widely used in electrical equipment in the electric power, post and telecommunications, petroleum, coal, metallurgy, railway, municipal and other departments , Automatic control and dispatching system. The AC current and voltage transmitters have a single-channel and three-channel combined structure. The connection method of current transmitter is divided into single-phase and three-phase current transmitter. Among them, a single-phase transmitter can input a secondary current from a current transformer, either phase A, B, or C. The three-phase current transmitter can input the three-phase current from the current transformer, generally the secondary current of the A, B, and C phase transformers, the corresponding output is three-way output, and the commonly used is 4-20MA DC current . In addition, a working power supply is required, both DC24V and AC220V are available. The six wires you mentioned may be three-phase current transducers. The performance advantages of the current transmitter 1. It is not easily affected by parasitic thermocouples and the resistance voltage drop and temperature drift along the wire. The transmission line can use very cheap and thinner twisted pair wires;   2, when the output resistance of the current source is large enough, The voltage induced by the magnetic field coupling into the wire loop will not have a significant impact, because the current caused by the interference source is very small, and the twisted pair can generally be used to resist and reduce the interference;    3. Capacitive interference will cause errors related to the receiver resistance For a 4-20mA two-wire loop, the receiver resistance is usually 250Ω (sampling Uoutu003d1~5V). This resistance is too small to produce a significant error. Therefore, the allowable wire length is longer and farther than the voltage telemetry system  4. Each single display device or recording device can be switched between different channels with unequal wire lengths, without the difference in accuracy due to unequal wire lengths;    5. Use 4mA for zero level to make judgments Open circuit or sensor damage (0mA state) is very convenient.  6. u200bu200bIt is easy to add surge and lightning protection devices to the two-wire output port, which is beneficial to safety, lightning protection and explosion protection.
Guangdong Kaidi Energy Technology Co., Ltd. is dedicated to servicing our customers with a wide array of high-quality service and products.
With continuous operational improvements, expanding capacity and a strong competitive position for serving strategic domestic markets, Guangdong Kaidi Energy Technology Co., Ltd. are positioned for long-term growth that will benefit our customers and investors.
customized level indicator level gauge is one of the most commonly used tool for customized level indicator.
Guangdong Kaidi Energy Technology Co., Ltd. is an online resource for today's modern woman to live a green, healthy, and happy life. We offer level gauge, customized level indicator and more! Pls visit our site at Kaidi level indicator to know more.
To deal with commercial threats, Guangdong Kaidi Energy Technology Co., Ltd. konws that the notion of proactively seeking out potential or looming external threats against a company is gaining traction.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...