Home   |   INFO CENTER   |   NEWS   |  

Dealing with the problems of radar level meter from several aspects

Home  >  INFO CENTER  >  NEWS  > 

Dealing with the problems of radar level meter from several aspects

Dealing with the problems of radar level meter from several aspects

2023-02-08

With the continuous improvement of automation level, radar level meter is used more and more widely. In the use process, the radar level meter will also appear big or small problems. For these problems, our consistent solution idea is to find out the cause of the failure and solve the problem according to the cause. In fact, there is another way of thinking, is to solve the problem directly.

news-Dealing with the problems of radar level meter from several aspects-Kaidi Sensors-img

Speaking of which, perhaps you are confused, are not sure why and how to solve the problem. Life, electrical equipment can not run the situation, our most initial solution is not to unplug the power or restart the device! Radar level meter problems can actually do the same.


First, disconnect the power supply, restart the device. Radar level meter installation environment is complex and variable, there are spherical tanks, vertical tanks; small tanks, large tanks; indoor installation, outdoor installation. If we all adopt the method of unloading to find the cause, it undoubtedly increases the difficulty. Therefore, when there is a problem with the radar level meter, you may want to disconnect the power, restart the equipment, and see if the level meter runs normally after restarting.

news-Kaidi Sensors-img

Next, debugging by debugging software. Radar level meter often appear problems, such as data jumping, data unchanged, data deviation from the actual value is too large or too small, and so on. These problems are sometimes caused by errors in the determination of the range, and sometimes caused by false echoes. By re-commissioning, such problems can be completely solved.


Again, replace the installation position. If the debugging, the fault still can not be eliminated, we have to observe the installation position of the vega radar level transmitter, to see if it is too close to the feeding port, to see if the radar level meter is installed in the conical tank above the feeding port, and so on. If the installation position is found to be unreasonable, the problem can be solved by replacing the installation position.


Finally, if the above methods are unable to solve the problem, you need to carry out the last step, disassemble the radar level meter, wipe the antenna. Sometimes the inaccuracy of the radar level meter is due to excessive adhesion on the antenna, which affects the transmitting and receiving signals.

news-Kaidi Sensors-Dealing with the problems of radar level meter from several aspects-img

The above several radar level meter processing methods, some processing process to know the reason, some fault processing is completed, the reason is still unknown. Therefore, I suggest that we spend some time afterwards to find the cause, after all, from the root cause of the problem is to really solve the problem.

Chat Online 编辑模式下无法使用
Leave Your Message inputting...