What should I do if the
radar level gauge is inaccurate in measurement? Compared with other measuring instruments, radar level gauges have a wider range of applications and have more advantages in installation and use. What errors do radar level gauges often have? Usually, the error of the radar level gauge is mainly due to the error in the installation of the instrument, which will cause the echo signal to be disturbed, resulting in measurement error. For this reason, the height of the tank and the size of the beam angle must be considered during installation, and a sufficient installation space should be reserved for the radar level gauge. In addition, the following common errors will also occur: 1: Measurement dead zone: The radar level gauge outputs a current of 4 to 20 mA during measurement. Due to the measured medium itself and the probe, in its measurement There are two dead zones, an upper dead zone and a lower dead zone. The minimum distance that can be measured between the liquid level in the upper dead zone and the upper reference point is about 0.1m~0.5m; the lower dead zone is at the bottom of the probe. With the change of the actual liquid level in the tank, the measurement results are not part of the change. 2: Error caused by the measured medium: When measuring the interface, the dielectric constant of the liquid above must be 10 larger than the dielectric constant of the liquid surface below. If the dielectric constant of the two interfaces is not much different, it will become a wave mode. During measurement, since the time used for the liquid level and the boundary level is basically the same, the two returned signals will be overlapped, which will affect the measurement result. 3: The viscosity of the liquid to be measured is too large: the medium has a high viscosity, such a liquid medium is likely to adhere to the probe, affecting the transmission of the signal and causing errors in the measurement. If the viscosity is higher, the medium and the probe will appear. Connected together, at this time, the probe must be cleaned regularly. 4: The error generated by the radar level gauge itself: the error caused by the improper installation of the radar level gauge on site. 5. The roughness of the inner wall of the waveguide causes abnormal radar echoes. The installation requirements of the radar level gauge with the waveguide are relatively high, especially the smoothness of the inner wall of the waveguide. The still-pipe is recommended to be made of stainless steel, and the still-pipe welding method is adopted. In order to effectively avoid these possible problems, when installing the
radar level meter, the following points should be paid attention to: 1. When installing the radar level meter, the feed port, feed curtain and vortex should be avoided, because the medium will produce amplitude during injection. False echoes that are much larger than the effective echoes reflected by the measured liquid level. At the same time, the irregular liquid level caused by the vortex will scatter the microwave signal, which will cause the attenuation of the effective signal, so they should be avoided; 2. For the container with a stirrer, the installation position of the radar level gauge should not be near the stirrer , because an irregular vortex will be generated during stirring, which will cause the attenuation of the radar signal. At the same time, the blades of the stirrer will also cause false echoes to the microwave signal, especially when the relative permittivity of the measured object is small and the liquid level is low, the impact of the stirrer is more serious; 3. When the radar liquid level When the meter is used to measure the liquid level of corrosive and easy-to-crystallize objects, in order to prevent the influence of the medium on the sensor, the manufacturer generally adopts a structure with a PTFE measuring window and a separation flange. The temperature of these parts should not be too high, the temperature of PTFE is 200 ℃. In order to avoid the influence of high temperature on the radar antenna, and to prevent the crystals existing on the diaphragm from affecting the normal operation of the instrument, a safety distance of at least 100-800mm is required between the flange end face and the high liquid level. How to solve the accuracy problem of the radar level gauge: First of all, when using the guided wave radar level gauge, you must pay attention to the measurement range. Exceeding the range will not only get accurate measurement data, but also may cause damage to the radar level gauge. damage. The measurement range should be calculated from the bottom of the tank touched by the light wave. If the storage tank is special and the bottom is concave, at this time the material level is lower than the calculation point, and the measurement cannot be performed. Secondly, when measuring low dielectric constant medium, if its material level is lower than the liquid level measurement value, and the bottom of the tank is visible, to make the measurement value more accurate, you can adjust the zero point upward to higher than the bottom of the tank. Location. Although it is said that the measurement range value can reach the top of the antenna tip, this is only an ideal situation. In reality, the effect of adhesion needs to be considered, so try to fix the measurement value at least 100mm away from the top of the antenna. Finally, if the measured medium is in constant motion, in order to ensure the accuracy of the measurement, it is recommended to fix the still-pipe at the bottom of the storage tank on site, and then fix it in the middle. During the welding process, it is necessary to ensure that the inner wall of the still-pipe is In order to prevent the bumps from hindering the guided wave, it is also necessary to ensure the smoothness of the welding.
Whenever the question of level gauge customized level indicator is raised, one comes across the term ''.
Guangdong Kaidi Energy Technology Co., Ltd.’s purpose is to create superior value for our customers, employees, communities and investors through the production, conversion, delivery and sale of energy and energy services.
Once we have a good idea of how level gauge can satisfy customer’s needs, consider whether we should create a skill for their demands.
A wholesaler should have many customized level indicator based products that could help you if you have a customized level indicator problem. It is better to treat the problem early rather than have to deal with it later. Guangdong Kaidi Energy Technology Co., Ltd. is your best choice.
level gauge, is an alternative product for customized level indicator to investors and consumers who are passionate about our products or services.