loading
Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors intelligent radar level meter supply for work
Kaidi Sensors intelligent radar level meter supply for work

Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work
  • Kaidi Sensors intelligent radar level meter supply for work

Kaidi Sensors intelligent radar level meter supply for work

With its properties like intelligent radar level meter, intelligent radar level meter occupy a magnificent place in intelligent radar level meter market.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

Principle

The general principle of the FM continuous wave radar level gauge is that the radar emits electromagnetic waves on the top of the tank, and the electromagnetic waves are received by the radar after being reflected by the medium. The frequency difference δf between the received signal and the transmitted signal is proportional to the distance R from the surface of the medium: R=C (speed)*δf (frequency difference)/2/K (frequency modulation slope). Because the speed of light C and the frequency modulation slope K are known, the frequency difference δf can be estimated to obtain the distance R from the radar installation position to the material surface, and then through the known total height of the tank, subtract the spatial distance from the radar to the material surface (referred to as Empty height) to get the height of the material level.

   
       

Kaidi Sensors intelligent radar level meter supply for work-1


Characteristic

1. Millimeter-wave radar, with a measurement accuracy of up to ±1mm, and a minimum blind area of 0.1m.

2. The smaller antenna size satisfies the measurement of more working conditions.

3. A variety of lens antennas, smaller launch angle, more concentrated energy, stronger echo signal, under the same industrial and mining conditions, compared to other radar products have higher reliability.

4. With stronger penetrability, it can be used normally even if there is adhesion and condensation.

5. The dynamic signal range is larger, and the measurement of low dielectric constant medium is more stable.

6. A variety of measurement modes, the radar reaction time in the fast measurement mode is less than 1S.


 FWM-15 Product Introducion


Kaidi Sensors intelligent radar level meter supply for work-2

Measuring medium: liquid

Measuring range: 0.3m~30m

Process connection: flange ≥DN80

Process temperature: -40~200℃

Process pressure: -0.1~2.5 MPa

Antenna size:76mm lens antenna

Antenna material: PTFE

Accuracy: ±2mm

Protection level: IP67

Center frequency: 80GHz

Launch angle:3°

Power source:  Two-wire system/DC24V

Four-wire system/AC220V

Six-wire system/DC12-24V

Shell: Aluminum/Plastic/Stainless steel

Signal output: Two-wire system/4...20mA/HART protocol

                          Four-wire system/4...20mA/HART protocol

                          Six-wire system/4...20mA/HART Protocol

Installation Requirements

  • Installation method 1:Flange mounting

When using flange mounting, the minimum distance between the meter and the tank wall should be 200mm.

Note: ①Datum     

         ②Container center or axis of symmetry 

                                                    Kaidi Sensors intelligent radar level meter supply for work-3


  • Installation method 2:Hoisting

(selected according to specific installation conditions)

                                                                      Kaidi Sensors intelligent radar level meter supply for work-4                  Kaidi Sensors intelligent radar level meter supply for work-5

   

  • Installation requirements:

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.                        

                                      Kaidi Sensors intelligent radar level meter supply for work-6         Kaidi Sensors intelligent radar level meter supply for work-7                      Kaidi Sensors intelligent radar level meter supply for work-8

         

Under extremely complex working conditions, the instrument  can work normally with the radar installation point as the center and no obstacles in the area with a radius of 20 cm.                            

     

Kaidi Sensors intelligent radar level meter supply for work-9

  • Schematic diagram of installation and takeover

The maximum installation stub height H max depends on the installation stub diameter D and the product launch angle.

Long installation and takeover will affect radar performance.                                             

                 

Kaidi Sensors intelligent radar level meter supply for work-10


Elecitical Connections

  • Power Supply

(4~20) mA(2-wire)

The power supply and the output current signal share a two-core shielded cable. See technical data for specific power supply voltage range.

(4~20) mA(4/6-wire)

The power supply needs to be supplied separately, and the power supply and the current signal use a four-core shielded cable (the current signal and the RS485 interface can be output at the same time, and the output needs to use a six-core shielded cable).

Modbus-RS485

The power supply needs to be supplied separately, and the power supply and the digital use a four-core shielded cable (the current signal and the RS485 interface can be output at the same time, and the output needs to use a six-core shielded cable).


  • Connection method

Ø 24V two-wire system wiring diagram is as follows:   

    

Ø Two-wire and two-chamber wiring diagram shown on the side is as follows:  

 Kaidi Sensors intelligent radar level meter supply for work-11

Ø Four-wire, two-room wiring diagram:    

       Kaidi Sensors intelligent radar level meter supply for work-12Kaidi Sensors intelligent radar level meter supply for work-13


Ø six-wire wiring diagram of the four-wire system is as follows:

      Kaidi Sensors intelligent radar level meter supply for work-14


  • Safety guidance

Please observe the requirements of the local electrical installation regulations!

Please observe local regulations regarding the health and safety of personnel. All operations on the electrical components of the instrument must be performed by trained professionals.

Please check the nameplate of the instrument to ensure that the product specifications meet your requirements. Make sure that the supply voltage is the same as that on the instrument nameplate.

  • Protection level

This instrument fully meets the requirements of protection grade IP66/67. Please ensure the waterproof performance of the cable gland. As shown below:

Kaidi Sensors intelligent radar level meter supply for work-15How to ensure that the installation meets the requirements of IP67:

Make sure the seal head is not damaged.

Make sure the cable is not damaged.

Make sure that the cable you are using meets the electrical connection specifications.

Before entering the electrical interface, bend the cable down to ensure that water does not flow into the housing, see ①

Please tighten the cable gland, see ②

Please block the unused electrical interface with a blind plug, see ③






Structure Size 

  • The outer casing size  (unit: mm)


  • Aluminum case:                    

  • Kaidi Sensors intelligent radar level meter supply for work-16


  • Stainless steel case:               

  • Kaidi Sensors intelligent radar level meter supply for work-17


  • Product Size  (unit: mm)                

    

Kaidi Sensors intelligent radar level meter supply for work-18


Technical Parameters

Process Connection                                                           Flange / material PP, PTFE, stainless steel, stainless steel +PTFE flanging

Antenna Material                                                                PTFE

The outer shell                                                                   Cast aluminum / stainless steel / plastic ABS     

The seal between the shell and the shell cover                 Silicone rubber

Casing window                                                                   Polycarbonate

The ground terminal                                                           Stainless steel


Power supply pressure

  • 2-wire system (single cavity/double cavity)              (15-28) V DC

                                                                                            Power dissipation     max 80mA  DC24V/ 2W

                                                                                            Allowable ripple    <100Hz                    Uss < lV

                                                                                                                        (100~100K) Hz        Uss < l0mV 

  •  Double chamber housing                          (198~242)V AC   4-wire system

                                                                             110V AC          4-wire system 


Cable parameter                           

Cable entrance / plug                        1  M20×l.5 cable entrance

                                                          1  blind plug M20×l.5

Terminal                                            Conductor cross section 2.5mm² 


Output parameters                           

Output signal                                     (4~20) mA /HART

Resolution                                         1mm

Fault signal                                       current output unchanged;20. 5mA;22mA;3.9mA

Integration time                                 (0~20)s, adjustable

Blind zone                                         0.1m/0.2m/0.3m

Maximum measuring distance          30 m

Measurement interval                       1 second (depending on parameter settings)

Adjustment time                                about 1 second (depending on parameter settings)

Working storage and transportation temperature                (-40~80) ℃  

Relative humidity                               ˂ 95%

Pressure                                            Max. 2.5MPa

Shockproof                                        Vibration frequency (10~150) Hz,

                                                          Maximum vibration acceleration l0m/s²


Meter Linearity

  • Beam angle

The beam angle is the beam angle when the radar wave energy density reaches half of its maximum value (3dB width). Microwaves emit signals outside the beam range and can be reflected by interference objects.

                                                                                                      Kaidi Sensors intelligent radar level meter supply for work-19   Kaidi Sensors intelligent radar level meter supply for work-20



The larger the antenna size, the smaller the beam Angle alpha, the less the interference echo will be generated.

For more accurate measurements, avoid installing any internal devices (such as limit switches, temperature sensors, bases, vacuum rings, heating coils, baffles, etc.) within the signal beam range.

Gauge linear 

Kaidi Sensors intelligent radar level meter supply for work-21



Product Model Selection

 FMW15

License

P    Standard  (Non-explosion-proof) 

I     Intrinsically safeExia IIC T6 Ga

D    Intrinsically safe+FlameproofExd ia IIC T6 Gb                                                         

Process Connection / Material

            1    G3.5A Thread

2    FlangeDN80 (Stainless steel + PTFE)                   

X     Special customization

Flange option / material

Specification / Code / Material

PP

PTFE

Stainless steel304+PTFE

Stainless steel316L+PTFE

DN80

-

-

G4

S4

DN100

-

-

G5

S5

DN125

-

-

G6

S6

DN150

-

-

G7

S7

 

Antenna Type / Material

A  76mm filled lens antenna/PTFE

Sealing / process temperature

B    EPDM/-40-200℃

                          Y     Special customization

The  Electronic Unit

1  4~20mA/HART protocol 24VDC   2-wire 

2  4~20mA/HART protocol 220VAC   4-wire   

3  4~20mA+RS485/Modbus protocol 12- 24VDC   6-wire                      

Shell material/protection grade

A   Cast aluminum / Single chamber / IP67

B   Cast aluminum / Double chamber / IP67

C   Cast aluminum / Double cavity side view / IP67

D   Plastic ABS / Single chamber / IP65

E   Stainless steel 304 / Single chamber / IP67

Cable Line

M   M20×l. 5

N    ½″ NPT

X     Special customization    

Display programming

A     Programming with display

B    With display programming

/ Bluetooth communication

C    Without           



As our intelligent radar level meter are made of intelligent radar level meter, they are both intelligent radar level meter.
The body frame of intelligent radar level meter can be intelligent radar level meter.
intelligent radar level meter is intelligent radar level meter, thus realizing the hope of intelligent radar level meter.
intelligent radar level meter are likely to possess features likeintelligent radar level meter.
Our intelligent radar level meter have a wide range of material category, taking different processes.
Different from other normal products, intelligent radar level meter enjoys a better quality with healthy materials.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...