Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors guided wave radar level transmitter factory for industrial
Kaidi Sensors guided wave radar level transmitter factory for industrial

Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial

Kaidi Sensors guided wave radar level transmitter factory for industrial

guided wave radar level transmitter It is manufactured with fine processing technology, with hard and firm texture, safe and reliable quality, long service life and wide application range. It is widely used in building curtain walls, door frames, furniture, automobiles and other places.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of level of liquid, slurry, granule and lump material, suitable for temperature and pressure changes; occasions where inert gas and volatilization exist.


It adopts the measurement method of microwave pulse, and can work normally in the industrial frequency band range. Low beam energy, can be installed in a variety of metal, non-metallic containers or pipes, no harm to human body and the environment.

Kaidi Sensors guided wave radar level transmitter factory for industrial-1

THE PRODUCT PRINCIPLE

Very short microwave pulses of very low energy are transmitted and received through an antenna system. The radar wave travels at the speed of light. The running time can be converted into a level signal by means of electronic components. A special time-stretching method ensures stable and accurate measurements in a very short time. Even in the case of complex conditions and spurious echoes, the level echoes can be accurately analyzed using microprocessor technology and commissioning software.

Kaidi Sensors guided wave radar level transmitter factory for industrial-2

The antenna receives the reflected microwave pulses and transmits them to the electronics. The microprocessor processes this signal and identifies the echoes generated by the micropulses on the material surface. The correct identification of the echo signal is done by the pulse software with an accuracy of millimeters.


The distance D from the material surface is proportional to the time travel T of the pulse: D=C×T/2; where C is the speed of light. Since the distance E from the empty tank is known, the level L is: L = E - D.


It is set by entering the empty tank height E (=zero), full tank height F (=full range) and some application parameters, which will automatically adapt the instrument to the measurement environment. Corresponds to 4-20mA output.

PROTECTION GRADE

This instrument fully meets the requirements of protection class IP66/67. Please make sure that the cable sealing head is waterproof. As shown

How to ensure that the installation meets the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please ensure that the cable is not damaged.

Please ensure that the cable used meets the requirements of the electrical connection specification.

Before entering the electrical connection, bend the cable downwards to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please plug the unused electrical connections with blind plugs, see ③Kaidi Sensors guided wave radar level transmitter factory for industrial-3

PRODUCT SPECIFICATION

Kaidi Sensors guided wave radar level transmitter factory for industrial-4

APPEARANCE OF SIZE

Kaidi Sensors guided wave radar level transmitter factory for industrial-5

TECHNICAL PARAMETERS

General data Material Antenna PTFE, PP

Housing Aluminum, plastic, antistatic PP, stainless steel 316

Seal between housing and enclosure Silicone rubber

Housing sight glass Polycarbonate

Grounding terminal Stainless steel

Process connection HBRD801 G1½″A thread or 1½″NPT thread / flange

KD802 PTFE Flanged Flange

KD803 Stainless Steel Flange

KD804 Stainless Steel Flange

KD805 Stainless Steel Flange

KD806 Stainless Steel Flange

Power supply voltage Two-wire system Standard type (16~26)V DC

Intrinsically safe (21.6~26.4)V DC

Power consumption max. 22.5mA

Allowable ripple

- <100Hz Uss < lV

- (100~100K)Hz Uss < l0mV

Flameproof type (22. 8 to 26. 4) V DC Two-wire system

  (198~242) V AC 4-wire / 110V AC 4-wire

Power consumption max. 1VA, 1W

Cable parameters Cable inlet/plug 1 M20xl.5 cable inlet (cable diameter 5 to 9 mm)

1 blind plug M20xl.5

Spring terminal block for wire cross section 2.5 mm²

Output parameters Output signal (4 to 20)mA/HART

Resolution 1.6μA

Fault signal Current output constant; 20.5mA; 22mA; 3.9mA

Two-wire load resistance See figure below

Four-wire load resistance 500Ω max.

Integration time (0 to 36)s, adjustable

Characteristic parameters Blind area End of antenna

KD801 20m (liquid)

KD802 20m (liquid)

KD803 35m

KD804 35m

KD805 20m

KD806 15m

Measurement interval approx. 1s (depending on parameter setting)

Adjustment time approx. 1s (depending on parameter setting)

Resolution 1mm

Accuracy 10mm or <0.1% (see accuracy diagram below)

Operating storage and transport temperature (-40 to 80) °C

Process temperature (temperature of antenna section)

KD801 -40~130℃

KD802 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD803 -40~130℃ (Standard type) / -40~180℃ (High temperature type)

KD804 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD805 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD806 (-40~400)℃

Relative humidity <95%

Pressure inside the tank Max. 4MPa

Shock resistance Mechanical vibration l0m/s² , (10~150)Hz

                                                                                                                                                         

Kaidi Sensors guided wave radar level transmitter factory for industrial-6

Kaidi Sensors guided wave radar level transmitter factory for industrial-7

INSTALLATION REQUIREMENTS

Recommended location (2), the tank wall to the outer wall of the installation short pipe should meet the following requirements: the best distance from the tank wall is 1/4 or 1/6 of the tank diameter, the minimum installation distance from the tank wall is 1/10 of the measurement range. for example: 10m level tank, the minimum installation distance from the tank wall should be 1m.

Kaidi Sensors guided wave radar level transmitter factory for industrial-8

● Cannot be installed above the inlet (4)


● It cannot be installed in the center (3). If it is installed in the center, multiple false echoes will be generated and the interference echoes will cause the real signal to be lost.


● If the distance between the instrument and the tank wall cannot be maintained, the medium on the tank wall will adhere to cause false echoes, and false echoes should be stored during the commissioning of the instrument.

                                                               Kaidi Sensors guided wave radar level transmitter factory for industrial-9                       Kaidi Sensors guided wave radar level transmitter factory for industrial-10                                     Kaidi Sensors guided wave radar level transmitter factory for industrial-11

                                                                  Kaidi Sensors guided wave radar level transmitter factory for industrial-12                                       Kaidi Sensors guided wave radar level transmitter factory for industrial-13                                   Kaidi Sensors guided wave radar level transmitter factory for industrial-14


guided wave radar level transmitter The design is scientific and reasonable, the structure is tight and compact, the power is strong, and the operation is stable. It can meet the needs of 24-hour industrial production. It is durable and has a long service life.
guided wave radar level transmitter Made of high-quality materials, advanced technology and exquisite craftsmanship, the surface is smooth and smooth, the texture is hard and thick, and it is not easy to rust and deform even after long-term use.
guided wave radar level transmitter Selected high-quality environmentally friendly materials, refined with sophisticated manufacturing technology and craftsmanship, environmentally safe, high-quality, is your quality choice.
guided wave radar level transmitter is made of high-quality materials and refined by advanced manufacturing technology and fine processing technology. The surface is polished and smooth, and the hand feels hard and thick. Drainage, fire protection, construction and other industries have applications.
guided wave radar level transmitter The selection of materials is excellent, the materials used are full, the shelf life is long, the scope of application is wide, the products are genuine, and they have received rave reviews in the market.
The product is both practical and aesthetically appealing. The design is carried out from the point of view of ergonomic and the designers adopt the newest clothing trends. Its key components are made of stainless steel which is durable in use
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...