loading
Kaidi Sensors  >  AI - Page Sitemap  >  Kaidi Sensors guided wave radar level transmitter factory for industrial
Kaidi Sensors guided wave radar level transmitter factory for industrial

Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial
  • Kaidi Sensors guided wave radar level transmitter factory for industrial

Kaidi Sensors guided wave radar level transmitter factory for industrial

[企业简称] has introduced and mastered advanced sheet metal processing technology, and the processed guided wave radar level transmitter has high dimensional accuracy, accurate bending angle, clean and tidy, and excellent texture.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of level of liquid, slurry, granule and lump material, suitable for temperature and pressure changes; occasions where inert gas and volatilization exist.


It adopts the measurement method of microwave pulse, and can work normally in the industrial frequency band range. Low beam energy, can be installed in a variety of metal, non-metallic containers or pipes, no harm to human body and the environment.

Kaidi Sensors guided wave radar level transmitter factory for industrial-1

THE PRODUCT PRINCIPLE

Very short microwave pulses of very low energy are transmitted and received through an antenna system. The radar wave travels at the speed of light. The running time can be converted into a level signal by means of electronic components. A special time-stretching method ensures stable and accurate measurements in a very short time. Even in the case of complex conditions and spurious echoes, the level echoes can be accurately analyzed using microprocessor technology and commissioning software.

Kaidi Sensors guided wave radar level transmitter factory for industrial-2

The antenna receives the reflected microwave pulses and transmits them to the electronics. The microprocessor processes this signal and identifies the echoes generated by the micropulses on the material surface. The correct identification of the echo signal is done by the pulse software with an accuracy of millimeters.


The distance D from the material surface is proportional to the time travel T of the pulse: D=C×T/2; where C is the speed of light. Since the distance E from the empty tank is known, the level L is: L = E - D.


It is set by entering the empty tank height E (=zero), full tank height F (=full range) and some application parameters, which will automatically adapt the instrument to the measurement environment. Corresponds to 4-20mA output.

PROTECTION GRADE

This instrument fully meets the requirements of protection class IP66/67. Please make sure that the cable sealing head is waterproof. As shown

How to ensure that the installation meets the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please ensure that the cable is not damaged.

Please ensure that the cable used meets the requirements of the electrical connection specification.

Before entering the electrical connection, bend the cable downwards to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please plug the unused electrical connections with blind plugs, see ③Kaidi Sensors guided wave radar level transmitter factory for industrial-3

PRODUCT SPECIFICATION

Kaidi Sensors guided wave radar level transmitter factory for industrial-4

APPEARANCE OF SIZE

Kaidi Sensors guided wave radar level transmitter factory for industrial-5

TECHNICAL PARAMETERS

General data Material Antenna PTFE, PP

Housing Aluminum, plastic, antistatic PP, stainless steel 316

Seal between housing and enclosure Silicone rubber

Housing sight glass Polycarbonate

Grounding terminal Stainless steel

Process connection HBRD801 G1½″A thread or 1½″NPT thread / flange

KD802 PTFE Flanged Flange

KD803 Stainless Steel Flange

KD804 Stainless Steel Flange

KD805 Stainless Steel Flange

KD806 Stainless Steel Flange

Power supply voltage Two-wire system Standard type (16~26)V DC

Intrinsically safe (21.6~26.4)V DC

Power consumption max. 22.5mA

Allowable ripple

- <100Hz Uss < lV

- (100~100K)Hz Uss < l0mV

Flameproof type (22. 8 to 26. 4) V DC Two-wire system

  (198~242) V AC 4-wire / 110V AC 4-wire

Power consumption max. 1VA, 1W

Cable parameters Cable inlet/plug 1 M20xl.5 cable inlet (cable diameter 5 to 9 mm)

1 blind plug M20xl.5

Spring terminal block for wire cross section 2.5 mm²

Output parameters Output signal (4 to 20)mA/HART

Resolution 1.6μA

Fault signal Current output constant; 20.5mA; 22mA; 3.9mA

Two-wire load resistance See figure below

Four-wire load resistance 500Ω max.

Integration time (0 to 36)s, adjustable

Characteristic parameters Blind area End of antenna

KD801 20m (liquid)

KD802 20m (liquid)

KD803 35m

KD804 35m

KD805 20m

KD806 15m

Measurement interval approx. 1s (depending on parameter setting)

Adjustment time approx. 1s (depending on parameter setting)

Resolution 1mm

Accuracy 10mm or <0.1% (see accuracy diagram below)

Operating storage and transport temperature (-40 to 80) °C

Process temperature (temperature of antenna section)

KD801 -40~130℃

KD802 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD803 -40~130℃ (Standard type) / -40~180℃ (High temperature type)

KD804 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD805 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD806 (-40~400)℃

Relative humidity <95%

Pressure inside the tank Max. 4MPa

Shock resistance Mechanical vibration l0m/s² , (10~150)Hz

                                                                                                                                                         

Kaidi Sensors guided wave radar level transmitter factory for industrial-6

Kaidi Sensors guided wave radar level transmitter factory for industrial-7

INSTALLATION REQUIREMENTS

Recommended location (2), the tank wall to the outer wall of the installation short pipe should meet the following requirements: the best distance from the tank wall is 1/4 or 1/6 of the tank diameter, the minimum installation distance from the tank wall is 1/10 of the measurement range. for example: 10m level tank, the minimum installation distance from the tank wall should be 1m.

Kaidi Sensors guided wave radar level transmitter factory for industrial-8

● Cannot be installed above the inlet (4)


● It cannot be installed in the center (3). If it is installed in the center, multiple false echoes will be generated and the interference echoes will cause the real signal to be lost.


● If the distance between the instrument and the tank wall cannot be maintained, the medium on the tank wall will adhere to cause false echoes, and false echoes should be stored during the commissioning of the instrument.

                                                               Kaidi Sensors guided wave radar level transmitter factory for industrial-9                       Kaidi Sensors guided wave radar level transmitter factory for industrial-10                                     Kaidi Sensors guided wave radar level transmitter factory for industrial-11

                                                                  Kaidi Sensors guided wave radar level transmitter factory for industrial-12                                       Kaidi Sensors guided wave radar level transmitter factory for industrial-13                                   Kaidi Sensors guided wave radar level transmitter factory for industrial-14


guided wave radar level transmitter actively absorbs foreign advanced production experience, and uses new technology and new technology to produce guided wave radar level transmitter. The manufactured guided wave radar level transmitter is exquisite in workmanship, stable in performance and high in quality, and is favored by customers.
guided wave radar level transmitter Equipped with an adjustable lamp tube, you can freely adjust the angle of the lamp tube according to your own needs, which is convenient for lighting work.
guided wave radar level transmitter It is made of high-quality materials, thick materials, exquisite workmanship, and high quality. It is both beautiful and practical. It is suitable for storing lotion, toner, liquid foundation and other cosmetics.
The shape of guided wave radar level transmitter perfectly embodies the innocent and lively nature of children, and is deeply loved by children.
guided wave radar level transmitter’s heating and humidifying system uses stainless steel electric heating tubes to heat the water in the box through automatic adjustment to maintain the temperature and humidity in the box, thereby creating an environment suitable for bread fermentation.
guided wave radar level transmitter has excellent characteristics: guided wave radar level transmitter. With integrated temperature monitoring for the battery, it features range in temperature revise
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...