Kaidi Sensors  >  AI - Page Sitemap  >  KAIDI conveyor belt trip switches for business for work
KAIDI conveyor belt trip switches for business for work

KAIDI conveyor belt trip switches for business for work
  • KAIDI conveyor belt trip switches for business for work
  • KAIDI conveyor belt trip switches for business for work

KAIDI conveyor belt trip switches for business for work

Once the cell assembly is complete, Kaidi Sensors conveyor belt trip switches must be put through at least one precisely controlled charge/discharge cycle to activate the working materials. Pattern printing can be customized on this product
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

Belt Sway Switch is a protective switch for detecting the meandering (sway or deviation) of belt conveyors, and sends out an alarm signal and an emergency stop signal.

It’s suited to be used for belt breakage prevention and orefalling prevention due to the belt sway. Widely used in iron and steel, cement and chemical plants, thermal power plants, etc., since it is essential for safety operation of belt conveyors.

The BELT SWAY SWITCH functions in two waysDetecting any deviation or sway in the conveyor belt and providing an alarm and sending out signal to stop the conveyor.

Use of this switch in material transport system can prevent damage to the conveyor belt and/or drive system and avoid consequential confusion on transport lines in the event of an accident.

FEATURES

The Belt Sway Switch is constructed with high reliability micro switches, lubricate less ball bearings, a touch pulley which is tilted to 750, and other parts ; its functions are designed with a large margin for sure action and long life .The switch has the difference of 20 between ON and OFF, to switch certainly at an action point. Therefore,this switch can prevent belt conveyor troubles by a simple circuit

 SPECIFICATIONS

Reset mode

Manual

Number of contacts

1a1b

Contact capacity

AC:90-380V, 5A

Switch angle Level 1

20°

Actuating Force

3.4-5.4N  (0.35~0.55kgf)

Switch angle Level 2

35°

Ambient   temperature

-20 °C ~ +60 °C

Weatherproof Type.

IP67

Color code

Y100M20C70BL50

Cable connection

8 ~ 12mm

 

 WIRING DIAGRAM

KAIDI conveyor belt trip switches for business for work-1

DRAWING

KAIDI conveyor belt trip switches for business for work-2

ENVIRONMENTAL CONDITIONS

The Belt Sway Switch should be used in the following environmental conditions; especially made products should be used at the allowable conditions noted in the approved drawing or the final drawing.

l  Temperature:  -10°C ~ +50°C

Do not use the Belt Sway Switch in the place where there is danger of freezing.

l  Humidity less than 80%

l  Dust

If much dust adheres to the touch roller and it solidifies the Belt Sway Switch will not move normally. To prevent dust from adhering to the touch roller, it should be cleaned at regular intervals.

INSTALLATION

Fitting bolts

The fitting bolts should be prepared before installation, and should be fitted into the mounting holes according to their length.

Mounting Base

The mounting base fitted to the belt conveyor should be prepared before installation. When you are deciding the dimensions of the mounting base, refer to Fig.2.

Installation

The dimension from the position of installation to the top of the idler of the belt conveyor should be fixed at 160 millimeters.

MAINTENANCE

Periodic Inspection

(1)Cleaning

Always clean when an excessive amount of dust accumulates on the touch roller.

(2)Wear of Touch Roller

Check wear of the touch roller . When 2 millimeters are worn off the roller, replace as explained in 6.3.

(3)Confirmation of Action

Check to see if the Belt Sway Switch is working normally by testing the touch roller.

Lubrication

The Belt Sway Switch has no need to lubricate.

Replacement of Touch Roller

By loosening the 12 millimeters-sized nut, the touch roller can be taken off easily from the lever.

Secure the nut when the touch roller is replaced, or the Belt Sway Switch may cause trouble if the nut comes loose .

Tightening of Cover

When taking off the cover of Belt Sway Switch for the sake of writing, adjusting and checking, secure the screws of the cover after working, or the Belt Sway Switch may cause trouble due to water and dust entering from between the cover and casing.



Kaidi Sensors conveyor belt trip switches is carefully checked in the overall application system, making sure it can meet all requirements of the storage battery industry. The product is often used in the automotive painting, circuit board (PCB) processing, and mending and bunding
Kaidi Sensors conveyor belt trip switches is manufactured by our professional workers who draw on their many years of know-how and experience in catalysis and materials science. The product is available in many different sizes and viscosity levels
The processes of Kaidi Sensors conveyor belt trip switches involve blending the raw materials, specialized grinding of the raw materials, inert atmosphere firing of the raw materials, and a final grind of the finished product. With strong acrylic adhesive, the product is distinguished by excellent holding force
Throughout the manufacturing process of Kaidi Sensors conveyor belt trip switches, tight tolerances and strict process controls are essential to ensure that there is no contamination, physical damage on the electrodes. The product can offer certain buffering from the impact
Kaidi Sensors conveyor belt trip switches is mainly composed of shell, cover, feed hole plug, connecting plate, connecting column, plate separator, and electrolyte. There is no residual glue after stripped off
conveyor belt trip switches is manufactured based on superior materials. It has good corrosion resistance, heat resistance, explosion-proof and sealing performance. By virtue of built-in battery pack, it has large capacity, high power, and excellent charge and discharge performance.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...