loading
Kaidi Sensors | Level gauge & level indicator manufacturer
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 1
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 2
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 3
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 4
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 1
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 2
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 3
Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4 4

Kaidi KD-YFLDIntelligent integrated split electromagnetic flowmeter Measurement of sewage pulp slurry acid and alkali resistant large caliber electromagnetic flowmeter4

Outer Covering::
5-10 days
Process temperature:
1 SET
Payments:
40℃~130℃
Vibration Frequency:
6 GHz
Inquiry
Power Source
Two-wire (DC24V) ;Four-wire(DC24V/AC220V)

Suitable for Medium:Liquid,   slightly corrosive liquid
Explosion-proof Grade: Exia IIC T6 Ga/ Exd   IIC T6 Gb 
Measuring Range: 20m 
Aerials: The Rod Antenna  ( PP /PTFE ) 
Frequency: 6 GHz
Temperature: (-40 ~ 130)
Measurement Precision:  ±10mm 
Process Pressure: (-0.1 ~ 0.3) Mpa
The signal Output: (4 ~ 20) mA/HART 
The Scene Display: Four LCD /Can be   programmed
Power Source: Two-wire (DC24V) Four-wire (DC24V/AC220V) 
Repeatability: ± 1mm 
Outer Covering : Aluminum /Plastic /   Stainless steel
Connection: Flange (optional) /   Thread

image.png

image.png 



1.   Dimensions  of  Instruments

 l  The rod antenna radar size (unit: mm)

image.png

l  Flange Selection (unit: mm)

image.png

2.   The  Electrical  Connection 

l  The power supply voltage:


(4~20)mA/HART (Two wire system)       The power supply and   the output current signal sharing a two core shield cable. The supply voltage   range see technical data. For intrinsically safe type must be a safety   barrier between the power supply and the instrument.
(4~20)mA/HART(Four wire system)      Separate   power supply and the current signal, respectively using a two-core shielded   cable. The supply voltage range see technical data.
RS485 / Modbus                                      Power supply and Modbus signal line are   separated, respectively using a two-core shielded cable, the power supply   voltage range see technical data.

l  Connection  mode:


 Ø  24V two wire wiring diagram as follows:

                                                                   image.png

Ø  220V four wire connection is as below:

                                                                  image.png

Ø  6~24V RS485/Modbus wiring diagram as follows:

                                                       image.png


l  Explosion Proof Connection

The intrinsic safety version sensors (Exia IIc T6) use Alu-die casting housing and filling Silicone rubber sealants internal structure aimed to prevent sparks resulted from circuit failure from leaking out. It is applicable for the continuous level measurement of flammable medium under Exia IIc T6.

A safety barrier FBS-2 must be used together with the intrinsic safety instrument. It is an associated device to this product for the power supply of this product. The main specification is intrinsic safety: Exia IIC, voltage of power supply: 24V DC±5%, short-circuit current: 135mA, operating current: 4...20mA.

All cables must be shielded. The max length is 500m for the cable from the barrier to the sensor. Stray capacitor0.1μF/Km, stray inductance 1mH/Km. Instrument must be connected to the ground potential. Any unapproved associated device is not allowed to be used.

image.png





Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.

CONTACT US

Attn: Mr. Joe Zou
Email:info86kd@gmail.com | info@kaidi86.com
Tel: +86 756 8652289
Fax: +86 756 8652290
Mob: +86 18198790863 (whatsapp/Wechat Same Number)
Add: Nanping Science and TechnologyPark, No.8 Pingdong 6th Road,Xiangzhou, Zhuhai, China

BETTER TOUCH BETTER BUSINESS

Contact Sales at KAIDI level gauge manufacturer.

Copyright © 2026 Kaidi Sensors | Sitemap | Privacy Policy
Customer service
detect