Kaidi Sensors  >  AI - Page Sitemap  >  high-quality level 2 radar supply for transportation
high-quality level 2 radar supply for transportation

high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation
  • high-quality level 2 radar supply for transportation

high-quality level 2 radar supply for transportation

Normal and special working technologies have been adopted in Kaidi Sensors level 2 radar production. Its mechanical parts will be treated by normal processing such as welding, cutting, and honing, and special processing such as precision casting, laser processing, and ultrasonic machining. It has high tensile strength and can be deformed without breakage
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

PRODUCT OVERVIEW

6GHz intelligent series radar level meter is suitable for non-contact continuous measurement of level of liquid, slurry, granule and lump material, suitable for temperature and pressure changes; occasions where inert gas and volatilization exist.


It adopts the measurement method of microwave pulse, and can work normally in the industrial frequency band range. Low beam energy, can be installed in a variety of metal, non-metallic containers or pipes, no harm to human body and the environment.

high-quality level 2 radar supply for transportation-1

THE PRODUCT PRINCIPLE

Very short microwave pulses of very low energy are transmitted and received through an antenna system. The radar wave travels at the speed of light. The running time can be converted into a level signal by means of electronic components. A special time-stretching method ensures stable and accurate measurements in a very short time. Even in the case of complex conditions and spurious echoes, the level echoes can be accurately analyzed using microprocessor technology and commissioning software.

high-quality level 2 radar supply for transportation-2

The antenna receives the reflected microwave pulses and transmits them to the electronics. The microprocessor processes this signal and identifies the echoes generated by the micropulses on the material surface. The correct identification of the echo signal is done by the pulse software with an accuracy of millimeters.


The distance D from the material surface is proportional to the time travel T of the pulse: D=C×T/2; where C is the speed of light. Since the distance E from the empty tank is known, the level L is: L = E - D.


It is set by entering the empty tank height E (=zero), full tank height F (=full range) and some application parameters, which will automatically adapt the instrument to the measurement environment. Corresponds to 4-20mA output.

PROTECTION GRADE

This instrument fully meets the requirements of protection class IP66/67. Please make sure that the cable sealing head is waterproof. As shown

How to ensure that the installation meets the requirements of IP67:

Please make sure that the sealing head is not damaged.

Please ensure that the cable is not damaged.

Please ensure that the cable used meets the requirements of the electrical connection specification.

Before entering the electrical connection, bend the cable downwards to ensure that water does not flow into the housing, see ①

Please tighten the cable sealing head, see ②

Please plug the unused electrical connections with blind plugs, see ③high-quality level 2 radar supply for transportation-3

PRODUCT SPECIFICATION

high-quality level 2 radar supply for transportation-4

APPEARANCE OF SIZE

high-quality level 2 radar supply for transportation-5

TECHNICAL PARAMETERS

General data Material Antenna PTFE, PP

Housing Aluminum, plastic, antistatic PP, stainless steel 316

Seal between housing and enclosure Silicone rubber

Housing sight glass Polycarbonate

Grounding terminal Stainless steel

Process connection HBRD801 G1½″A thread or 1½″NPT thread / flange

KD802 PTFE Flanged Flange

KD803 Stainless Steel Flange

KD804 Stainless Steel Flange

KD805 Stainless Steel Flange

KD806 Stainless Steel Flange

Power supply voltage Two-wire system Standard type (16~26)V DC

Intrinsically safe (21.6~26.4)V DC

Power consumption max. 22.5mA

Allowable ripple

- <100Hz Uss < lV

- (100~100K)Hz Uss < l0mV

Flameproof type (22. 8 to 26. 4) V DC Two-wire system

  (198~242) V AC 4-wire / 110V AC 4-wire

Power consumption max. 1VA, 1W

Cable parameters Cable inlet/plug 1 M20xl.5 cable inlet (cable diameter 5 to 9 mm)

1 blind plug M20xl.5

Spring terminal block for wire cross section 2.5 mm²

Output parameters Output signal (4 to 20)mA/HART

Resolution 1.6μA

Fault signal Current output constant; 20.5mA; 22mA; 3.9mA

Two-wire load resistance See figure below

Four-wire load resistance 500Ω max.

Integration time (0 to 36)s, adjustable

Characteristic parameters Blind area End of antenna

KD801 20m (liquid)

KD802 20m (liquid)

KD803 35m

KD804 35m

KD805 20m

KD806 15m

Measurement interval approx. 1s (depending on parameter setting)

Adjustment time approx. 1s (depending on parameter setting)

Resolution 1mm

Accuracy 10mm or <0.1% (see accuracy diagram below)

Operating storage and transport temperature (-40 to 80) °C

Process temperature (temperature of antenna section)

KD801 -40~130℃

KD802 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD803 -40~130℃ (Standard type) / -40~180℃ (High temperature type)

KD804 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD805 -40~130℃ (standard type) / -40~180℃ (high temperature type)

KD806 (-40~400)℃

Relative humidity <95%

Pressure inside the tank Max. 4MPa

Shock resistance Mechanical vibration l0m/s² , (10~150)Hz

                                                                                                                                                         

high-quality level 2 radar supply for transportation-6

high-quality level 2 radar supply for transportation-7

INSTALLATION REQUIREMENTS

Recommended location (2), the tank wall to the outer wall of the installation short pipe should meet the following requirements: the best distance from the tank wall is 1/4 or 1/6 of the tank diameter, the minimum installation distance from the tank wall is 1/10 of the measurement range. for example: 10m level tank, the minimum installation distance from the tank wall should be 1m.

high-quality level 2 radar supply for transportation-8

● Cannot be installed above the inlet (4)


● It cannot be installed in the center (3). If it is installed in the center, multiple false echoes will be generated and the interference echoes will cause the real signal to be lost.


● If the distance between the instrument and the tank wall cannot be maintained, the medium on the tank wall will adhere to cause false echoes, and false echoes should be stored during the commissioning of the instrument.

                                                               high-quality level 2 radar supply for transportation-9                       high-quality level 2 radar supply for transportation-10                                     high-quality level 2 radar supply for transportation-11

                                                                  high-quality level 2 radar supply for transportation-12                                       high-quality level 2 radar supply for transportation-13                                   high-quality level 2 radar supply for transportation-14


Materials Requirement Planning (MRP) is one of the main factors in Kaidi Sensors level 2 radar production. Materials used in the product are required to be tested in terms of strength, mechanical properties, and durability. It totally conforms to the UL Flame Rating of 94V-0
The design principles of Kaidi Sensors level 2 radar mainly include the following aspects: stiffness and rigidity of the separate constructional elements and their combined behavior under load as well as operational movements. It stands out for its impact endurance performance
The materials for making Kaidi Sensors level 2 radar are carefully selected by the QC team. Its materials feature excellent mechanical characteristics and physical properties which are required in the heavy-duty machine operation. It can reduce the electrical signal loss and provides the highest efficiency
Kaidi Sensors level 2 radar is an inter infiltration result of various technologies. It is developed by the R&D team who adopts the mechanical technique, detection and sensing technology, automatic control technology, and servo drive technology. It is characterized by high thermal conductivity and good heat dissipation
The design considerations of Kaidi Sensors level 2 radar cover the following aspects: static and dynamic stiffness, operational speeds, gearboxes, manual, and automatic control. It can be manufactured with a customized thickness
Our qualified team effectively controls this high quality product by implementing the quality control system. With a solder mask, it enjoys a good electrical insulation property
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...